首页> 外文会议>IEEE Energy Conversion Congress and Exposition >Online Degradation Detection Method for Voltage Regulation and Efficiency in Digitally-Controlled Switching Mode Power Supply
【24h】

Online Degradation Detection Method for Voltage Regulation and Efficiency in Digitally-Controlled Switching Mode Power Supply

机译:数控开关电源稳压和效率在线退化检测方法

获取原文

摘要

The software-implemented online-degradation-detection method for digitally-controlled switching mode power supply (DC-SMPS) was studied. We found the voltage regulation degradation and the efficiency degradation are different output current dependence on applied duty. They are separately detectable by comparing the applied and the theoretical duty, which is calculated using micro-processing unit (MPU) fetched input/output IV data and pre-measured efficiency. This method is easily implementable as firmware and expected as a cost and space effective degradation detection/failure prediction method. In this paper, we describe the concept and verify it using MATLAB/Simulink simulation and RCP (Rapid Control Prototyping) evaluation.
机译:研究了数字控制的开关电源(DC-SMPS)的软件在线退化检测方法。我们发现电压调节性能下降和效率下降是不同的输出电流对所施加占空比的依赖。通过比较施加的占空比和理论占空比,可以分别检测它们,该占空比是使用微处理单元(MPU)提取的输入/输出IV数据和预先测量的效率计算得出的。该方法可以容易地实现为固件,并且可以预期为成本和空间有效的劣化检测/故障预测方法。在本文中,我们描述了这一概念,并使用MATLAB / Simulink仿真和RCP(快速控制原型)评估对其进行了验证。