This paper proposes open-switch fault diagnosis and tolerant control methods for a Vienna rectifier using bidirectional switches. The proposed diagnosis method detects the open-switch fault by using only the input currents without the additional devices. In addition, a position of the open-switch fault detected by the proposed diagnosis method is used to apply the proposed tolerant control. The proposed tolerant control is implemented by modifying the reference voltages of the Vienna rectifier. The proposed tolerant control can mitigate the ripple component in the dc-link voltage and improve the performance in terms of the current total harmonic distortion compared to when any tolerant control is not applied. The effectiveness and performance of the proposed diagnosis and tolerant control methods are verified by simulation.
机译:本文提出了一种使用双向开关的维也纳整流器的开路开关故障诊断和容错控制方法。所提出的诊断方法通过仅使用输入电流而不使用附加设备来检测开路开关故障。另外,通过所提出的诊断方法检测到的开路开关故障的位置被用于施加所提出的公差控制。通过修改维也纳整流器的参考电压来实现所建议的公差控制。与不采用任何容忍控制时相比,所提出的容忍控制可以减轻直流链路电压中的纹波分量,并改善当前总谐波失真的性能。通过仿真验证了所提出的诊断和容错控制方法的有效性和性能。