The converter with a single-phase rectifier, a dc-link circuit and a three-phase inverter is widely applied in high-speed railway electrical traction drive system. The fault frequency of single-phase rectifier is higher than that of three-phase inverter. Thus, this paper presents a new and fast model-based approach for open-switch fault diagnosis of the single-phase pulse width modulation rectifier, based on the mixed logical dynamic model and residual generation. It requires no additional hardware but only some measurements and command signals which are available in control system. This diagnosis method is quite suitable for electrical traction application due to the fast diagnosis time, simple structure and high reliability. Experimental results confirm the effectiveness and accuracy of the proposed algorithm. It is shown that such diagnosis method can locate the faulty switch in a few milliseconds which is important to avoid catastrophic consequences.
机译:具有单相整流器,直流环节电路和三相逆变器的变流器广泛应用于高速铁路电力牵引驱动系统。单相整流器的故障频率高于三相逆变器的故障频率。因此,本文基于混合逻辑动态模型和残差生成,提出了一种基于模型的快速新方法,用于单相脉宽调制整流器的开路故障诊断。它不需要额外的硬件,只需要控制系统中可用的一些测量和命令信号即可。该诊断方法诊断时间快,结构简单,可靠性高,非常适合电力牵引应用。实验结果证明了该算法的有效性和准确性。结果表明,这种诊断方法可以在几毫秒内定位故障开关,这对于避免灾难性后果很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号