首页> 外文会议>IEEE Electrical Power and Energy Conference >Demand Control of Baseboard Heaters: Lessons Learned from 50-home Pilot Study
【24h】

Demand Control of Baseboard Heaters: Lessons Learned from 50-home Pilot Study

机译:踢脚线加热器的需求控制:50户试点研究的经验教训

获取原文

摘要

This paper presents results from a pilot study in 50 occupied homes in Fredericton, New Brunswick, Canada to evaluate a demand response (DR) strategy applied to residential electric baseboard heating loads. The underlying principle is based on storing electricity as thermal energy in the building envelope and household contents before the grid peak demand period, and then discharging that stored energy to maintain conditions for thermal comfort during the peak period. During January and February 2016, a total of 13 DR interventions were executed. This field test showed that a load shift up to a maximum of 3.4 kW, with an average of 1.4 kW, per household was possible for the first hour, depending on the outdoor temperature. We observed a large variation in load shift between homes, partly depending on the thermostat set-point profiles, building and occupant characteristics. The approach holds significant potential for shifting peak loads in locations where electricity is a major source of energy for space heating.
机译:本文介绍了在加拿大新不伦瑞克省弗雷德里克顿的50个住宅中进行的一项试验研究的结果,以评估应用于住宅电气踢脚线供暖负荷的需求响应(DR)策略。基本原理是基于在电网高峰需求期之前将电能作为热能存储在建筑物的围护结构和家庭住所中,然后释放所存储的能量以维持高峰期的热舒适条件。在2016年1月和2016年2月,总共执行了13项DR干预措施。这项现场测试表明,根据室外温度的不同,每个家庭在头一个小时内最多可将负载移动至最大3.4 kW,平均为1.4 kW。我们观察到房屋之间的负载变化很大,部分取决于恒温器设定点曲线,建筑物和居住者的特征。该方法在移动电力是空间供暖主要能源的位置的峰值负载方面具有巨大潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号