The paper comprises an overview of state-of-theart methods to drive multiply paralleled IGBT power stages. Typical drawbacks of these approaches are summarized and the logical conclusion a totally delay matched and low jitter configuration that allows clustering of up to 12 individual power blades by individually digitally tuned gate drivers is presented. The measurement of existing standard solutions and the results of the described totally matched approach are shown and the corresponding topologies and experimental switching test results are presented in this paper.
机译:本文概述了驱动多个并联IGBT功率级的最新方法。总结了这些方法的典型缺陷,并给出了逻辑结论:一个完全延迟匹配且低抖动的配置,该配置允许通过单独的数字调谐栅极驱动器将多达12个单独的功率刀片进行群集。本文介绍了现有标准溶液的测量结果以及所述完全匹配方法的结果,并给出了相应的拓扑结构和实验性开关测试结果。