This paper investigates the effect of the utilization region on capacity degrading of lithium-ion batteries. The selected batteries of the approximately same initial full capacity are deliberately discharged by a constant current and charged by the constant current-constant voltage (CC-CV) scheme cyclically in three different ranges, low, middle, and high state-of-charge (SOC), with an equal amount of charge. After a great number of charging/discharging cycles, the batteries' full capacities are measured. Experimental results indicate that the least full capacity degradation happens to the battery operated in the high SOC range. In addition, the full capacity degradation of the battery operated in the low SOC range increases rather than decreases in the first 300 cycles. After 2860 charging/discharging cycles, the full capacities have been deteriorated to 94.01 %, 86.20 % and 88.70 % for batteries with high, middle and low operating ranges, respectively.
机译:本文研究了利用区对锂离子电池容量下降的影响。选定的初始满容量几乎相同的电池会通过恒定电流有意放电,并通过恒定电流恒定电压(CC-CV)方案在低,中和高充电状态三个不同范围内循环充电( SOC),且充电量相等。经过大量的充电/放电循环后,将测量电池的全部容量。实验结果表明,在高SOC范围内运行的电池发生的满电量下降最少。另外,在低SOC范围内工作的电池的满容量劣化在最初的300个循环中增加而不是减少。经过2860次充电/放电循环后,高,中和低工作范围的电池的总容量已分别下降至94.01%,86.20%和88.70%。