After experiencing multiple pipe breaks in a single area, the staff at The Las Vegas Valley Water District (LVVWD) began to suspect that pressure transient events were to blame. Though the District has one of the most sophisticated SCADA systems in the country, there was no direct evidence of significant transient events. The data provided by the traditional pressure monitoring equipment could not validate their suspicions. With the aim of getting more detailed pressure data, the District deployed a series of high sample rate pressure monitoring devices. Almost immediately the highly granular data not only confirmed their suspicion that transients were wreaking havoc, but revealed pressures nearly twice as high as what they had been capturing with their traditional data monitoring system. This case study reviews how LVVWD utilized the high sample rate pressure data to calm their systems and eliminate the source of damaging transients.
机译:在一个地区经历了多次管道破裂后,拉斯维加斯山谷水域(LVVWD)的工作人员开始怀疑是造成压力瞬变事件的罪魁祸首。尽管该学区拥有该国最复杂的SCADA系统之一,但没有直接证据表明发生了重大的瞬时事件。传统压力监测设备提供的数据无法证实其怀疑。为了获得更详细的压力数据,学区部署了一系列高采样率压力监测设备。几乎立即,高度粒度化的数据不仅证实了他们对瞬变正在造成严重破坏的怀疑,而且还揭示了其压力几乎是使用传统数据监控系统所捕获压力的两倍。本案例研究回顾了LVVWD如何利用高采样率压力数据来使系统稳定并消除破坏性瞬变的根源。