A modular UPS system is generally presented as having a much higher level of availability than a monolithic, double conversion, on-line UPS system. However, there are different types of modular UPS systems available on the market, with varying degrees of reliability and availability. To represent the strengths and weaknesses of each architecture and accurately compare them to one another, a detailed reliability model must be built. This paper presents a rational methodology to define and analyse each modular UPS system, and to identify its mode of operation and possible failure conditions. This methodology is then applied to the most common modular UPS architectures present on the market, highlighting the advantages and disadvantages of each, and making the differentiation between ordinary, good and excellent modular UPS system designs possible.
机译:通常,模块化UPS系统比单片,双重转换的在线UPS系统具有更高的可用性。但是,市场上有不同类型的模块化UPS系统,其可靠性和可用性程度各不相同。为了表示每种架构的优势和劣势并将它们彼此准确地进行比较,必须建立一个详细的可靠性模型。本文提出了一种合理的方法来定义和分析每个模块化UPS系统,并确定其操作模式和可能的故障情况。然后将这种方法应用于市场上最常见的模块化UPS体系结构,突出每种方法的优缺点,并使普通,优良和出色的模块化UPS系统设计之间的区别成为可能。