This paper proposes a power factor correction method of a non-resonant IPT system using a four-winding transformer. The proposed technique is applied to the IPT system with a dual active bridge converter to reduce conduction loss and winding loss. When two pairs of the primary-side and the secondary-side wires are connected in parallel, the low coupling coefficient between the wires driven by in-phase voltage corrects the power factor from the viewpoint of the power supply due to the improvement of an equivalent magnetic coupling. The effect of the power factor correction is assessed by experiments with two four-winding transformers, coupling coefficient of which is different from each other. As experimental results, it is confirmed that a maximum efficiency with the lower coupling coefficient between the parallel connected wires is improved by 3.0% in comparison with the system, which has the high coupling coefficient.
机译:本文提出了一种使用四绕组变压器的非谐振IPT系统的功率因数校正方法。所提出的技术被应用于具有双有源桥式转换器的IPT系统,以减少传导损耗和绕组损耗。当两对初级侧和次级侧导线并联连接时,由于等效性的提高,从同相电压驱动的导线之间的低耦合系数从电源的角度校正了功率因数。磁耦合。功率因数校正的效果是通过使用两个耦合系数互不相同的两个四绕组变压器进行实验来评估的。作为实验结果,证实了与具有高耦合系数的系统相比,在并联连接的导线之间具有较低耦合系数的最大效率提高了3.0%。