1. Impact of virtualized clocks and timers guest machine % Processor Time counters are distorted The Windows clock interrupt that drives CPU usage sampling is impacted Correction factor for CPU Usage measurement at the Process/Thread level 2. Difference counters that report a rate/sec can be impacted, although the events are still being counted correctly 3. Timestamps gathered using the rdtsc instruction are virtualied Guest OS sees "apparent time" such that successive invocations of rdtsc return monotonically increasing values e.g., the Windows counters that report Disk latency 4. Instantaneous counters remain valid sampled observations.
机译:1.虚拟时钟和计时器来宾计算机的影响处理器时间计数器%失真导致驱动CPU使用率采样的Windows时钟中断受到影响进程/线程级别的CPU使用率测量的校正因子2.报告速率/秒的差异计数器可以受影响,尽管仍然可以正确地对事件进行正确计数。3.使用rdtsc指令收集的时间戳已虚拟化。来宾OS看到“视在时间”,因此rdtsc的连续调用将返回单调递增的值,例如,报告磁盘延迟为4的Windows计数器。计数器仍然是有效的采样观测值。