首页> 外文会议>National conference on noise control engineering >Characterizing impact and airborne sound transmission performance of insulated concrete form floor-ceiling assemblies
【24h】

Characterizing impact and airborne sound transmission performance of insulated concrete form floor-ceiling assemblies

机译:表征隔热混凝土楼板-天花板组件的冲击和空气传播的声音

获取原文

摘要

Insulated concrete form (ICF) is a system of formwork for reinforced concrete construction typically composed of rigid expanded polystyrene (EPS). A 3 m (10') × 3.6 m (12') × 350mm (14") deep floor-ceiling assembly was constructed in the laboratory consisting of ICF forms in a steel frame. Concrete was poured into the floor-ceiling assembly and it was fixed into place between the source and receiving room of an accredited laboratory. The base assembly was tested to STC 51 and IIC 15. A combination of resilient floor underlayment and resilient ceiling isolation hangers were used with various finish floors to achieve STC values ranging from 51-64 and IIC ratings ranging from 15-69. This paper examines one-third octave band response of the ICF floor across a frequency range from 50-5000 Hz when tested according to ASTM E90 and ASTM E492.
机译:绝缘混凝土模板(ICF)是用于钢筋混凝土建筑的模板系统,通常由刚性膨胀聚苯乙烯(EPS)组成。在实验室中,用钢框架中的ICF模板构造了一个3 m(10')×3.6 m(12')×350mm(14“)深的地板-天花板组件。将混凝土倒入地板-天花板组件中,底座组件已通过STC 51和IIC 15的测试。将弹性地板垫层和弹性天花板隔离吊架与各种饰面地板结合使用,以达到STC值: IIC额定值为51-64,而IIC额定值为15-69,本文根据ASTM E90和ASTM E492在50-5000 Hz的频率范围内检查了ICF地板的三分之一倍频程响应。