The TAPIRO (TAratura Pila Rapida a Potenza zerO, Fast Pile Calibration at 0 Power) is a fast neutron source reactor located in the Centre of ENEA Casaccia, Italy. This research reactor has been operated since 1971 for investigation on neutron propagation in fast reactors components, fast neutron irradiation damage analysis supporting fusion energy program and aerospace applications, testing of innovative detectors for Large Hadron Collider programs, training and education. In the present paper a thermal-hydraulic analysis is carried out with different approaches to characterize the core cooling system of the TAPIRO reactor in order to compare the results obtained with the present methods and calculation tools, with those evaluated during the reactor project phase. Two different methods have been used for such analysis, one by TIESTE-MINOSSE code for a preliminary analysis and one by RELAP5-3D code for a best estimate analysis. Calculations concern the steady state at nominal power and two kinds of transients (loss of flow and a reactivity insertion). Comparison with experimental data has been performed.
机译:TAPIRO(塔拉图拉·皮拉·利必达a Potenza zerO,在0功率下快速桩定标)是位于意大利ENEA卡萨奇亚中心的快速中子源反应堆。该研究堆自1971年开始运行,用于研究快堆组件中的中子传播,支持聚变能程序和航空应用的快中子辐照损伤分析,大型强子对撞机程序的创新探测器的测试,培训和教育。在本文中,以不同的方法进行了热工水力分析,以表征TAPIRO反应堆的堆芯冷却系统,以便将使用本方法和计算工具获得的结果与在反应堆项目阶段进行评估的结果进行比较。两种不同的方法已用于这种分析,一种是通过TIESTE-MINOSSE代码进行的初步分析,另一种是通过RELAP5-3D代码进行的最佳估计分析。计算涉及额定功率下的稳态和两种瞬态(流量损失和反应性插入)。与实验数据进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号