首页> 外文会议>Canadian Society for Civil Engineering annual conference >EFFECT OF HORIZONTAL REINFORCEMENT ANCHORAGE END DETAIL ON SEISMIC PERFORMANCE OF REINFORCED MASONRY SHEAR WALLS
【24h】

EFFECT OF HORIZONTAL REINFORCEMENT ANCHORAGE END DETAIL ON SEISMIC PERFORMANCE OF REINFORCED MASONRY SHEAR WALLS

机译:水平钢筋锚固端细节对砌体剪力墙抗震性能的影响

获取原文

摘要

The most recent design codes for masonry structures necessitate the use of reinforced masonry (RM) shear walls in medium and high seismic areas. There are several factors that control the contribution of the horizontal reinforcement to the in-plane shear capacity of RM shear walls. One of these factors is its anchorage end detail. The current version of the Canadian Standards Association CSA S304-14 for design of masonry structures requires that the anchorage of the horizontal reinforcing bars in the plastic hinge region shall have a 90° or more standard hook at the ends of the wall. However, a 180° standard hook is required for ductile shear walls. On the other hand, some masonry design codes (e.g. New Zealand, NZS 4230:2004) permits a 90° anchorage hook for ductile walls. This paper discusses the results of three identical RM shear walls that were tested under in-plane axial compressive stress and cyclic lateral excitations. All the walls were dominated by shear failure before reaching their flexure capacity. Wall W-180° was constructed with a 180° hook while walls W-90° and W-Str had a 90° hook and straight bar. The test results show that a 180° hook is the most effective anchorage end detail in terms of lateral force capacity and ductility. However, wall W-Str reached a lateral resistance, Q_(ue), of 398 kN compared to 412 kN and 418 kN for walls W-90° and W-1800, respectively, with less than 5% difference. Moreover, wall W-180° achieved a high level of displacement ductility of 4.2 instead of 3.9 and 3.6 when using a 90° hook and straight bar at a drop in wall capacity to 80% of Q_(ue). More results are analyzed and presented in this paper according to force-based, displacement-based, and performance-based seismic design considerations.
机译:最新的砌体结构设计规范要求在中高地震地区使用增强的砌体(RM)剪力墙。有几个因素可以控制水平钢筋对RM剪力墙的面内剪力的影响。这些因素之一是其锚固端部细节。加拿大标准协会CSA S304-14的最新版本用于砌体结构设计,要求水平钢筋在塑料铰链区域中的锚固在墙的末端应具有90°或更大的标准钩。但是,对于延性剪力墙,需要使用180°标准挂钩。另一方面,一些砌体设计规范(例如,新西兰,NZS 4230:2004)允许将90°锚固钩用于延性墙。本文讨论了三个相同的RM剪力墙的结果,这些剪力墙在面内轴向压缩应力和循环侧向激励下进行了测试。在达到其挠曲能力之前,所有壁都受剪切破坏的支配。 W-180°墙采用180°挂钩,而W-90°和W-Str墙采用90°挂钩和直杆。测试结果表明,就侧向力能力和延展性而言,180°钩是最有效的锚固端部细节。但是,壁W-Str的侧向阻力Q_(ue)为398 kN,而壁W-90°和W-1800分别为412 kN和418 kN,相差不到5%。此外,在壁容量下降至Q_ue的80%时,使用90°钩和直杆时,W-180°壁的位移延展性达到了4.2的高水平,而不是3.9和3.6。根据基于力,基于位移和基于性能的抗震设计考虑,本文分析并提出了更多结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号