With the large-scale deployment of IED, the number of alarm signal increase dramatically, causing some problems such as invalid alarm and secondary alarm frequency, malfunctions of protective relays and circuit breakers and so on. Due to the lack of effective preprocessing of monitoring data, it is difficult for the operator to make the right judgment in a short time. To solve the above problems, this paper put forward an analysis method of the relationship between alarm signal action and sequential logic in smart substation. On the basis of IEC61850 standardized modeling and the filtering and classification of monitoring information, the configuration file and network topology analysis of substation system are analyzed, obtaining the relationship between the power element and the protection and circuit breaker, and a backtracking method based on time constraint and action logic is constructed by introducing the timing constraint of alarm information into the event chain. Finally, proved by an example, the method is correct and feasible.
机译:随着IED的大规模部署,报警信号的数量急剧增加,引起一些问题,如无效报警和二次报警频率,保护继电器和断路器故障等。由于缺乏对监控数据的有效预处理,操作员很难在短时间内做出正确的判断。针对上述问题,提出了智能变电站中报警信号动作与时序逻辑关系的分析方法。在IEC61850标准化建模的基础上,对监控信息进行过滤和分类,分析了变电站系统的配置文件和网络拓扑分析,获得了功率元件与保护断路器的关系,并提出了基于时间的回溯方法。约束和动作逻辑是通过将警报信息的时序约束引入事件链来构造的。最后通过实例验证了该方法的正确性和可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号