The most commonly used method to prevent hot spot formation of the PV module is to install the bypass diode. However, the traditional configuration of the electrical connection between its cells and bypass diodes exacerbates the power loss. It has been proposed that the door connection improved the output power obviously under most shading conditions but showed its disadvantages in the other cases. In this paper, the reconstruction method based on “door” connection is proposed. This new method can convert the PV modules gantry between the door connection and normal connection according to the different shading conditions, so as to optimize the output power. The detection criterion of the reconstruction method based on the door connection is proposed, as well as the implementation approach of this new method. Through simulation, this paper draw the conclusion that the reconstruction based on door connection has more superior over the output power.
机译:防止PV模块形成热点的最常用方法是安装旁路二极管。然而,其电池与旁路二极管之间的电连接的传统配置加剧了功率损耗。已经提出,在大多数遮蔽条件下,门连接明显改善了输出功率,但在其他情况下却显示出其缺点。本文提出了一种基于“门”连接的重建方法。这种新方法可以根据不同的遮蔽条件在门连接和普通连接之间转换光伏组件门架,从而优化输出功率。提出了基于门连接的重建方法的检测准则,以及该方法的实现方法。通过仿真,得出结论:基于门连接的重构比输出功率更优越。