首页> 外文会议>China International conference on electricity distribution >The application of UHF detection positioning method into the process of partial discharge detection of switch cabinet
【24h】

The application of UHF detection positioning method into the process of partial discharge detection of switch cabinet

机译:超高频检测定位方法在开关柜局部放电检测中的应用

获取原文

摘要

Partial discharge detection technology of switch cabinet is widely applied nationwide. It is necessary to judge whether the switch cabinet is abnormal by detecting TEV and ultrasonic signals of switch cabinet at preliminary stage. It is necessary to redetect the abnormal signals with UHF detection technology to judge whether it is discharged, determine discharge type, realize positioning of partial discharge and determine the damage degree of equipment. Based on partial discharge detection case of 10kV switch cabinet of certain transformer substation, the application of UHF detection method into partial discharge detection process of switch cabinet is introduced in this paper.
机译:开关柜局部放电检测技术已在全国范围内得到广泛应用。初步检查开关柜的TEV和超声信号,判断开关柜是否异常。要用超高频检测技术对异常信号进行重新检测,判断是否放电,确定放电类型,实现局部放电定位,确定设备的损坏程度。在某变电站10kV开关柜局部放电检测案例的基础上,介绍了UHF检测方法在开关柜局部放电检测过程中的应用。

著录项