Fault-tolerant methods have been recognized for improving the reliability of multi-phase bidirectional DC-DC converters, including current-fed and voltage-fed dual active bridge converters. Fault-tolerant research for voltage-fed dual active bridge converters has caught much attention recently. However, few fault-tolerant methods for current-fed dual active bridge (CF-DAB) converter have been developed because it becomes more challenging due to the asymmetrical structure between primary and secondary sides. In this paper, a new fault-tolerant CF-DAB converter with blocking capacitors is proposed. The operation of the converter when an open-circuit fault occurs in different fault scenarios of the CF-DAB converter is comprehensively analyzed. A frozen phase fault-tolerant method with additional blocking capacitors on both sides of the transformer is proposed. The aim of the use of blocking capacitors is to block the DC current component of the filter inductor from passing through the transformer, which could otherwise result in the saturation of the transformer. Also, the DC blocking capacitors help isolate the faulty phase when the frozen-phase fault-tolerant method is applied.
机译:已经识别容错方法用于提高多相双向DC-DC转换器的可靠性,包括电流馈电和电压馈电双极电桥转换器。电压馈电双极主电桥转换器的容错研究最近遇到了很多关注。然而,已经开发了几种用于电流馈电双极电桥(CF-DAB)转换器的容错方法,因为由于初级和次级侧的不对称结构,它变得更具挑战性。本文提出了一种具有阻塞电容器的新容错CF-DAB转换器。全面分析了在CF-DAB转换器的不同故障场景中发生开路故障时转换器的操作。提出了一种冻结相位容错方法,具有变压器两侧的附加阻塞电容器。使用阻塞电容器的目的是阻止滤波器电感的DC电流分量通过变压器,否则可能导致变压器的饱和。此外,当施加冻结相容错方法时,直流阻挡电容有助于隔离故障相位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号