摘要

It is known that particle accumulation is beneficial for dust removal in industry. In order to understand better particle accumulation mechanism, experiments were carried out to analyze the influence of flue gas temperature and humidity on ash accumulation. It is found that the Engineering Acid Dew Temperature (EADT) of flue gas is an important parameter that determines the efficiency of particle accumulation. When the gas temperature is lower than the EADT, the sulfuric acid in the flue gas and ash humidity rise dramatically, which leads to particle accumulation. In order to improve the collection efficiency, the flue gas temperature can be controlled to trigger particle accumulation.
机译:众所周知,颗粒积累有利于工业中的除尘。为了理解更好的粒子累积机制,进行了实验,以分析烟气温度和湿度对灰分积累的影响。结果发现烟气的工程酸露水(EADT)是确定粒子积累效率的重要参数。当气体温度低于EADT时,烟道气中的硫酸和灰湿度急剧上升,这导致颗粒积聚。为了提高收集效率,可以控制烟道气温度以触发粒子积聚。