首页> 外文会议>Chinese Society for Optical Engineering conferences >Transmission Characteristics of X-ray in MCP Collimator in Parallel Structure
【24h】

Transmission Characteristics of X-ray in MCP Collimator in Parallel Structure

机译:并联结构MCP准直器中X射线的传输特性

获取原文

摘要

In order to improve the imaging quality of X-ray and reduce the effects of X-ray and scatter line on image, the adoption of X-ray collimator is the most effective method. MCP collimator in parallel structure can effectively reduce the ratio of X-ray and scatter line to reach on image plane, and reduce the atomization degree of images, so as to improve the image contrast. Through the establishment first-order radiation transmittance model of MCP collimator, test the performance of MCP collimator, it is prove that the MCP collimator can be used in the imaging system that consists of proximity of X-ray image intensifier, first-order radiation transmittance calculation formula of MCP absorption type collimator in parallel structure is reduced, obtain the transmittance distribution non cosine curve distribution of MCP collimator through calculating.
机译:为了提高X射线的成像质量并减少X射线和散射线对图像的影响,采用X射线准直器是最有效的方法。并联结构的MCP准直器可以有效地降低X射线和散射线的比率到达图像平面,并降低图像的雾化程度,从而提高图像对比度。通过MCP准直器的建立一阶辐射透射率模型,测试MCP准直器的性能,证明了MCP准直器可用于成像系统,该成像系统包括X射线图像增强器的邻近辐射透射率平行结构中MCP吸收式准直器的计算公式减少,通过计算获得MCP准直器的透射分布非余弦曲线分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号