首页> 外文会议>Corrosion conference and expo >Corrosion Behavior of Buried Pipeline in Presence of AC Stray Current in Controlled Environment
【24h】

Corrosion Behavior of Buried Pipeline in Presence of AC Stray Current in Controlled Environment

机译:控制环境下交流杂散电流下埋地管道的腐蚀行为

获取原文

摘要

Alternate current (AC) corrosion is a frequent problem where pipelines share right of way with high power transmission lines, AC powered railed system, and structural components on subsea power units. The magnetic field produced by transmission power lines and AC power generators and converters induces an alternate electric current on the buried pipe; the magnitude of the induced AC being proportional to the voltage and separation distance. It has been reported that AC corrosion can occur even when the cathodic protection (CP) criteria is satisfied, highlighting the fact that AC interactions are not well understood. In the present work, corrosion rates of carbon steel samples in sodium chloride solutions with and without AC at different DC bias potentials were obtained by both electrochemical techniques and weight loss analysis. Results are compared and discussed together with polarization curves to obtain an assessment of electrochemical techniques, which are commonly applied for evaluation of AC induced corrosion. A correlation between corrosion rates obtained from weight loss and electrochemical techniques was obtained by comparing corrosion current densities estimated from weight loss values with those from polarization curves. These results are discussed in the context of differences in the anodic and cathodic Tafel slopes. Additionally, solution analyses were conducted during the test to quantify the ferrous/ferric ion content and solution pH. Stirring and continuous solution replacement were necessary to maintain a constant ferrous/ferric ion content and pH.
机译:交流电(AC)腐蚀是一个经常出现的问题,其中管线与大功率输电线路,AC供电的有轨系统以及海底动力装置上的结构部件共享通行权。输电线路,交流发电机和变流器产生的磁场在埋管上感应出交流电。感应交流电的大小与电压和分隔距离成正比。据报道,即使满足阴极保护(CP)标准,也会发生AC腐蚀,这突出说明了人们对AC相互作用的了解还不够充分。在目前的工作中,通过电化学技术和失重分析,获得了碳钢样品在氯化钠溶液中在有和没有交流电的情况下在不同的直流偏置电势下的腐蚀速率。将结果与极化曲线进行比较和讨论,以获得对电化学技术的评估,该技术通常用于评估交流感应腐蚀。通过比较根据重量损失值估算的腐蚀电流密度与根据极化曲线得出的腐蚀电流密度,可以得出重量损失与电化学技术获得的腐蚀速率之间的相关性。在阳极和阴极Tafel斜率的差异的背景下讨论了这些结果。另外,在测试过程中进行了溶液分析,以量化亚铁/铁离子含量和溶液pH值。为了保持恒定的亚铁/三价铁离子含量和pH值,必须进行搅拌和连续更换溶液。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号