Empirical compensation of low order harmonics due to flat top modulation the 'BATMAN' modulator

机译:通过平顶调制“ BATMAN”调制器对低次谐波进行经验补偿

获取原文

摘要

The 60° flat-top modulation technique (also called two phase or discontinuous modulation) is a widely used method in the industry to reduce switching losses in three phase PWM inverters. This technique reduces the number of switchings via adding a zero sequence component to the output voltage. The added component is chosen such that one of the phase legs is not switched, but the phase-to-phase voltage still remains sinusoidal. In this article it is shown that 60° flat-top modulation can cause low order harmonic distortion. The cause and the magnitude of this effect is investigated, and an empirical method is given to decrease the distortion, which uses a modified version of the 60° flat-top modulator. The new method significantly decreases the current THD, at the cost of a minor increase in converter losses.
机译:60°平顶调制技术(也称为两相或不连续调制)是工业上广泛使用的减少三相PWM逆变器开关损耗的方法。该技术通过在输出电压上增加零序分量来减少开关次数。选择增加的分量,以便不切换相脚之一,但相间电压仍保持正弦曲线。本文表明,60°平顶调制会引起低阶谐波失真。研究了这种影响的原因和严重程度,并给出了一种减少失真的经验方法,该方法使用了60°平顶调制器的改进版本。新方法大大降低了电流总谐波失真,但代价是转换器损耗略有增加。