Vibration control using tuned mass damper (TMD) for civil structures has been widely accepted and used in buildings and bridges. However, the TMD provides a frequency-dependent damping for the primary structure. The control effectiveness of TMD will vary with the frequency content of the excitation. A method to verify the control performance of TMD is lack in the literatures. In this study, two simple indicators were developed to judge the TMD control performance based on the theoretical derivation, which indicates the maximum power flow is occurred when the TMD stroke lags the structural displacement by ninety degree. The proposed indicators were verified by numerical simulation. The results show the proposed indicators can judge the effective of TMD correctly. In addition, the waveform of the instantaneous phase is helpful to adjust the TMD stiffness to the right value.
机译:用于民用结构的调谐质量阻尼器(TMD)的振动控制已被广泛接受并用于建筑物和桥梁。但是,TMD为主要结构提供了频率相关的阻尼。 TMD的控制效果将随着激励的频率含量而变化。验证TMD的控制性能的方法是缺乏文献中的。在这项研究中,开发了两种简单的指标以判断基于理论推导的TMD控制性能,这表明当TMD中风滞后于九十多程度时,表示当TMD中风滞后的最大功率流动。通过数值模拟验证了所提出的指标。结果表明,拟议的指标可以正确判断TMD的有效性。另外,瞬时相的波形有助于将TMD刚度调节到右值。