首页> 外文会议>IEEE International Ultrasonics Symposium >Improved vector velocity estimation using Directional Transverse Oscillation
【24h】

Improved vector velocity estimation using Directional Transverse Oscillation

机译:使用方向横向振荡的改进矢量速度估计

获取原文

摘要

A method for estimating vector velocities using transverse oscillation (TO) combined with directional beamforming is presented. Directional Transverse Oscillation (DTO) is self-calibrating, which increase the estimation accuracy and finds the lateral oscillation period automatically. A normal focused field is emitted and the received signals are beamformed in the lateral direction transverse to the ultrasound beam. A lateral oscillation is obtained by having a receive apodization waveform with two separate peaks. The IQ data are obtained by making a Hilbert transform of the directional signal, and a modified TO estimator can be used to find both the lateral and axial velocity. The approach is self-calibrating as the lateral oscillation period directly is estimated from the directional signal through a Fourier transform. The approach was implemented on the SARUS scanner using a BK Medical 8820e transducer with a focal point at 105.6 mm (F#=5) for Vector Flow Imaging (VFI). A 6 mm radius tube in a circulating flow rig was scanned and the parabolic volume flow of 112.7 l/h (peak velocity 0.55 m/s) measured by a Danfoss Magnetic flow meter for reference. Velocity estimates for DTO are found for 32 emissions at a 90 degrees beam-to-flow angle at a vessel depth of 30 mm. The standard deviation (SD) drops from 9.14% for TO to 5.4%, when using DTO. The bias is -5.05% and the angle is found within +/- 3.93 degrees. At 70 mm a relative SD of 7% is obtained, the bias is -1.74%, and the angle is found within +/- 2.6 degrees showing a low bias across depths.
机译:提出了一种结合横向振荡(TO)和定向波束形成的矢量速度估计方法。方向横向振荡(DTO)是自校准的,可以提高估计精度并自动找到横向振荡周期。发射正常的聚焦场,并且在垂直于超声波束的横向方向上对接收到的信号进行波束成形。通过使接收变迹波形具有两个单独的峰值,可获得横向振荡。 IQ数据是通过对方向信号进行希尔伯特(Hilbert)变换而获得的,并且可以使用改进的TO估计器来查找横向速度和轴向速度。该方法是自校准的,因为通过傅立叶变换直接从方向信号中估计出横向振荡周期。该方法是在SARUS扫描仪上使用BK Medical 8820e传感器实现的,该传感器的焦点为105.6毫米(F#= 5),用于矢量流成像(VFI)。扫描循环流动装置中一个半径为6 mm的管,并用Danfoss电磁流量计测量112.7 l / h的抛物线体积流量(峰值速度0.55 m / s)作为参考。在30 mm的容器深度下,以90度的束流角,对32种排放量发现了DTO的速度估算值。使用DTO时,标准偏差(SD)从TO的9.14%降至5.4%。偏差为-5.05%,角度为+/- 3.93度。在70毫米处,相对SD为7%,偏差为-1.74%,并且角度在+/- 2.6度范围内,显示整个深度的偏差较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号