This paper proposes a novel distributed architecture for controlling Heating, Ventilation and Air conditioning (HVAC) systems in commercial buildings. Zone Modules use local models and measurements to compute requests for HVAC service over various future time windows. These requests are expressed in terms of the heating/cooling service required which we can conceptually regard as tokens. A Central Scheduler balances token requests and allocates tokens to each zone for the next time slot. This allocation attempts to minimize total energy consumption while respecting operational constraints. Zone modules update their local models based on the measured thermal responses resulting from allocated tokens, and re-compute forward token requests. This proposed token based architecture is inspired by medium access control protocols in communication networks. It offers several advantages in the context of HVAC systems. The architecture is scalable to realistic buildings with 200–500 thermal zones, it is robust relative to non-stationary environmental conditions and unanticipated changes in user needs, and it is modular enabling low-cost deployment without requiring expensive custom thermal modeling of buildings. We develop the zone module algorithms for computing token requests and central scheduler algorithms to allocate tokens. Using simulation studies, we demonstrate that the performance loss of our token based scheduling strategy is modest in comparison to a fully centralized nonlinear optimal control scheme.
机译:本文提出了一种新颖的分布式体系结构,用于控制商业建筑中的供暖,通风和空调(HVAC)系统。区域模块使用本地模型和度量来计算未来各个时间段内对HVAC服务的请求。这些要求以所需的加热/冷却服务来表示,我们可以在概念上将其视为代币。中央调度程序平衡令牌请求并将令牌分配给下一个时隙的每个区域。这种分配试图在遵守操作约束的同时将总能耗降至最低。区域模块根据分配的令牌产生的测得的热响应来更新其本地模型,并重新计算前向令牌请求。所提出的基于令牌的体系结构受到通信网络中的媒体访问控制协议的启发。它在HVAC系统方面具有多个优势。该体系结构可扩展到具有200-500个热区的现实建筑,相对于非平稳环境条件和用户需求的意外变化具有鲁棒性,并且它是模块化的,可实现低成本部署,而无需进行昂贵的自定义建筑物热建模。我们开发了用于计算令牌请求的区域模块算法和用于分配令牌的中央调度程序算法。通过仿真研究,我们证明了与完全集中的非线性最优控制方案相比,基于令牌的调度策略的性能损失不大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号