SMART (System-integrated Modular Advanced ReacTor) was designed by the Korea Atomic Energy Research Institute (KAERI). The standard design approval for the SMART design was issued on July 4th 2012 by a Korean regulatory body. The main components include a pressurizer, steam generators, and reactor coolant pumps. They are installed in a reactor pressure vessel, and there are no large-size pipes. The safety systems could be simplified as an LBLOCA (Large-Break Loss of Coolant Accident) scenario is inherently excluded. An integral-effect test loop for SMART, SMART-ITL, has been constructed at KAERI. The objectives of SMART-ITL are to investigate and understand the integral performance of the reactor systems and components, and the thermal-hydraulic phenomena occurring in the system during normal, abnormal, and emergency conditions, and to verify the system safety during various design basis events of SMART. A series of small-break loss-of-coolant accident (SBLOCA) tests was performed by KAERI using the SMART-ITL. This paper presents the major results of an SBLOCA test for the safety injection system (SIS) line break. They have been analyzed using the best-estimate system code, MARS-KS, which was developed by KAERI to assess its simulation capability on the SBLOCA scenario for the SMART design. The scenarios of SBLOCA in the SMART design were reproduced well using the SMART-ITL facility and MARS-KS code. The simulation results using the MARS-KS code is in good agreement with the test results using the SMART-ITL.
机译:SMART(系统集成模块化先进反应堆)是由韩国原子能研究所(KAERI)设计的。韩国监管机构于2012年7月4日发布了SMART设计的标准设计批准书。主要组件包括增压器,蒸汽发生器和反应堆冷却剂泵。它们安装在反应堆压力容器中,没有大型管道。安全系统可以简化,因为本质上排除了LBLOCA(大面积冷却液泄漏事故)场景。 KAERI已构建了SMART的积分效应测试回路SMART-ITL。 SMART-ITL的目的是研究和了解反应堆系统和组件的整体性能,以及正常,异常和紧急情况下系统中发生的热工现象,并在各种设计基准下验证系统安全性。 SMART事件。 KAERI使用SMART-ITL进行了一系列的小型冷却液损失事故(SBLOCA)测试。本文介绍了安全注入系统(SIS)线路中断的SBLOCA测试的主要结果。他们使用最佳估计的系统代码MARS-KS进行了分析,该代码由KAERI开发,以评估其在SMART设计的SBLOCA方案中的仿真能力。使用SMART-ITL工具和MARS-KS代码很好地复制了SMART设计中的SBLOCA方案。使用MARS-KS代码的仿真结果与使用SMART-ITL的测试结果非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号