Many researchers have investigated the behavior of rock-socketed piles and related the uniaxial compressive strength of "intact" rock to pile shaft resistance without considering rock mass quality. This study presents results from a fully instrumented field-scale load test on a 0.2-m-diameter micropile socketed 4.2 m into limestone layers (2.7 m into weathered limestone and 1.5 m into hard limestone). The results show that practically no base resistance is mobilized until the pile head settlement reaches about 7% of the diameter of the test micropile. The measured limit shaft resistance values are compared with values predicted using methods available in the literature. The comparison indicates that use of the "intact" strength of the rock for estimation of limit shaft resistance may lead to an unconservative design when the rock mass quality is very poor, as indicated by, for example, low RQD values.
机译:许多研究人员已经研究了嵌岩桩的性能,并将“完整”岩石的单轴抗压强度与桩身阻力相关联,而没有考虑岩体质量。这项研究提供了在直径为0.2 m的微型桩上完全仪器化的现场测试的结果,该微型桩嵌在石灰岩层中4.2 m(风化石灰岩中为2.7 m,硬石灰岩中为1.5 m)。结果表明,直到桩头沉降量达到试验微颗粒直径的7%为止,几乎没有动员基层电阻。将测得的极限轴电阻值与使用文献中可用方法预测的值进行比较。比较表明,当岩石质量非常差时(例如由低RQD值指示),使用岩石的“完整”强度来估计极限竖井阻力可能会导致设计不保守。