Infection arises in 8.5% of primary and 12% of secondary spinal fusion surgeries. Because many of these infections are marked by the formation of biofilms, which are difficult to treat with systemic antibiotics, treatment options are often limited to revision surgery. In order to prevent infection, we are developing antibiotic-loaded vessels for localized ultrasound mediated drug delivery. Macro-porous PEEK pucks were loaded with methylene blue (MeB) and coated in poly(lactic acid). In vitro samples were submerged in 200 ml of saline solution and ultrasound was applied for 30 minutes (5 MHz, 3 MPa). Surrounding media was sampled over 8 days and the concentration of MeB measured via spectrophotometry. The release from sonicated samples was compared to unsonicated controls. In parallel, a single-reservoir ABS clip design was also loaded with a combination of VAN and MeB and coated with either one or two layers of PLA. Release was observed while samples were submerged in 200 ml of saline solution. No immediate release of MeB was observed after suspension of the loaded porous PEEK pucks, demonstrating complete coating. Solutions from the non-insonated control group showed a 26 % increase in MeB concentration 2 days after suspension, and then remained stable. Solution from the insonated (experimental group) showed a 757 % increase in MeB concentration relative to baseline levels over an 8-day period. Finally, porous PEEK vessels loaded with vancomycin (VAN), were implanted in a cadaverous bunny to test their efficacy in situ. Two sites were inoculated with 10 CFU S. aureus and another two sites were wrapped in plastic to capture released drug. Surgical sites in the cadaverous rabbit showed a 10x reduction in the concentration of bacteria, while sites wrapped in plastic caught 50% of the released drug. ABS clip prototype single-coated samples showed immediate leakage and complete release of drug after 48 hours. Double-coated samples completely retained drug a- ter 48 hours. Thus, feasibility of an ultrasound mediated drug delivery system was demonstrated in vitro and ex vivo.
机译:8.5%的原发性脊柱融合手术和12%的继发性脊柱融合手术感染。由于许多此类感染的特征在于生物膜的形成,很难用全身性抗生素治疗,因此治疗选择通常仅限于翻修手术。为了防止感染,我们正在开发装载抗生素的血管,用于局部超声介导的药物递送。将大孔PEEK圆盘装载亚甲基蓝(MeB),并涂上聚乳酸。将体外样品浸入200 ml盐溶液中,并施加超声30分钟(5 MHz,3 MPa)。在8天之内对周围介质进行采样,并通过分光光度法测量MeB的浓度。将超声处理后的样品的释放与未超声处理的对照进行比较。同时,单储层ABS夹子设计也加载了VAN和MeB的组合,并涂有一层或两层PLA。将样品浸入200 ml盐溶液中时观察到释放。悬浮的多孔PEEK圆盘悬浮后未观察到MeB立即释放,表明已完全包被。悬吊后2天,未给予声波的对照组的溶液中MeB浓度增加了26%,然后保持稳定。超声(实验组)的溶液在8天内相对于基线水平显示MeB浓度增加了757%。最后,将装有万古霉素(VAN)的多孔PEEK血管植入尸体兔子中,以原位测试其功效。用10 CFU金黄色葡萄球菌接种两个部位,用塑料包裹另外两个部位以捕获释放的药物。尸体兔子的手术部位细菌浓度降低了10倍,而用塑料包裹的部位捕获了50%的释放药物。 ABS夹子原型的单层涂层样品在48小时后显示立即渗漏并完全释放了药物。双层样品在48小时后完全保留了药物。因此,在体外和离体证明了超声介导的药物递送系统的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号