Performance Test Codes require primary mass flow accuracies that in many applications require the laboratory-quality calibration of differential pressure meters. It is also true that many performance tests are conducted at Reynolds numbers and flows well above the laboratories' capacities, and sound extrapolation methods had to be developed. Statistical curve-fits and regression analyses by themselves, absent fluid-dynamic foundations, are not valid procedures for extrapolation. The ASME PTC 19.5-2004 discharge coefficient equations presented in this paper are suitable for use and extrapolation of laboratory calibration data.
机译:性能测试代码需要大量质量流量精度,许多应用需要实验室质量校准差压计。还有很多性能测试在Reynolds号码中进行,并远远超过实验室的能力,并且必须开发出声的外推方法。统计曲线拟合和回归分析,不存在流体动态基础,是外推的有效程序。本文提出的ASME PTC 19.5-2004放电系数方程适用于实验室校准数据的使用和推断。