首页> 外文会议>International conference on applied biotechnology >Determination of Dichloromethane in Waste Water Using Headspace Gas Chromatography
【24h】

Determination of Dichloromethane in Waste Water Using Headspace Gas Chromatography

机译:顶空气相色谱法测定废水中的二氯甲烷

获取原文

摘要

A method for the detection of dichloromethane (DCM) in waste water was developed by using head-space gas chromatography with FID detection. The calibration curve was linear in three orders of magnitude range of DCM levels and the linear correlation coefficient was 0.9995. The limit of detection was 0.004 mg/l and the limit of quantitation was 0.01 mg/l. The system and method precision were both accord with the requirement. The method, practiced in the quantitative determination of DCM in waste water, solved many problems as such and high water content in sample. Many impurities which impacted the detection of DCM were separated visibly.
机译:利用顶空气相色谱-FID检测技术开发了一种检测废水中二氯甲烷(DCM)的方法。校准曲线在DCM水平的三个数量级范围内呈线性,线性相关系数为0.9995。检测限为0.004 mg / l,定量限为0.01 mg / l。系统和方法精度均符合要求。该方法用于废水中DCM的定量测定中,解决了许多问题,例如样品中的高水分含量。明显分离了许多影响DCM检测的杂质。