With the development of grid, the difference between peak load and valley load is more and more significant in mega-cities, making the regulation of voltage more and more difficult. Besides, users' reactive power compensation is unreasonable and often leads to the increased line losses and difficulties of voltage upward. This paper analyses the status quo of operation of reactive power in downtown and suburban areas of Shanghai. The main contradiction is noted that the current reactive power demand during peak hours is low as well as a large excess of valley hours. Based on the development requirements of the smart grid, it is pro posed to further enhance the energy saving benefits of the whole society. It is necessary to strengthen the assessment of users' reactive power. The assessment criteria of send d own reactive power should be standardized. It is also necessary to put forward the power factor requirements for users mentioned in the “Grid Corporation of power system voltage and reactive power quality regulations” which is issued by National State Grid Corporation in 2009.
机译:随着电网的发展,峰值负荷和谷负荷之间的差异在大型城市中越来越重要,使电压越来越困难。此外,用户的无功功率补偿是不合理的,并且通常导致增加的线损耗和电压向上困难。本文分析了上海市中心与郊区无功动力运作的现状。主要矛盾指出,高峰时段的电流无功功率需求低于谷数量的较低。根据智能电网的开发要求,专业推动进一步提升整个社会的节能益处。有必要加强对用户的无功功率的评估。 Send D自己无功功率的评估标准应标准化。在2009年由国家国家网格公司发布的“电力系统电压电流电压和无功功率质量法规”中提到的用户提出了用户的功率因数要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号