首页> 外文会议>IEEE Energy Conversion Congress and Exposition >Optimal Dual Constant Switching Frequency Control for CRM Buck-Buck/Boost PFC Converter
【24h】

Optimal Dual Constant Switching Frequency Control for CRM Buck-Buck/Boost PFC Converter

机译:CRM降压/升压PFC转换器的最佳双常开关频率控制

获取原文

摘要

Due to the dead zone in the average input current, the Buck power factor correction (PFC) converter is difficult to meet the design requirements in many applications. In order to solve the demerit, the Buck-Buck/Boost PFC converter has been proposed. However, the traditional critical conduction mode (CRM) Buck-Buck/Boost PFC converter adopts constant on-time (COT) control. Operating with COT, the switching frequency varies greatly during a line cycle. This complicates the design of the electromagnetic interference (EMI) filter. In this paper, an optimal dual constant switching frequency (DCF) control for CRM Buck-Buck/Boost converter is proposed. The switching frequency of the converter with DCF is fixed in Buck mode and Buck/Boost mode separately in a line cycle, and the PF can be improved by optimizing the switching frequency. The experimental results from a prototype of 120-W are given to verify the effectiveness of the proposed method.
机译:由于平均输入电流中的死区,降压功率因数校正(PFC)转换器难以满足许多应用中的设计要求。为了解决脱德,已经提出了降压/升压PFC转换器。然而,传统的临界传导模式(CRM)降压/升压PFC转换器采用恒定的准时(COT)控制。使用婴儿床操作,开关频率在线周期内变化大大变化。这使得电磁干扰(EMI)过滤器的设计复杂化。本文提出了一种用于CRM降压/升压转换器的最佳双常开关频率(DCF)控制。通过DCF的转换器的开关频率在线周期分开地以降压模式和降压/升压模式固定,并且可以通过优化开关频率来提高PF。给出了120-W的原型的实验结果,以验证所提出的方法的有效性。