SVPWM is widely applied in the control of the three-phase inverter. The phase angle of the grid takes part in the coordinate transformation and PLL is necessary. However, the non-ideal grid may affect the accuracy of the phase angle. To eliminate the influence of the non-ideal grid, the PLL technology should be improved and it may complicate the control strategy. This paper proposes a novel grid frequency tracking control strategy without PLL for three-phase inverter. The angle which takes part in the coordinate transformation is directly generated by the controller. The grid frequency tracking method can ensure that the changing rate of the generated angle is the same as that of the grid phase angle. But the phases of them may be different. The feasibility of the control strategy and the necessity of the frequency tracking are analyzed in detail. An 18 kVA DSP-based three-phase inverter has been established and tested. Simulation and experimental results verify the theoretical analysis.
机译:SVPWM广泛应用于三相逆变器的控制。网格的相位角参与坐标变换,并且需要PLL。然而,非理想网格可能会影响相位角的准确性。为消除非理想电网的影响,应提高PLL技术,并可能使控制策略复杂化。本文提出了一种新颖的网格频率跟踪控制策略,无需PLL,用于三相逆变器。控制器的角度由控制器直接生成坐标变换。电网频率跟踪方法可以确保产生角度的变化率与网格相位角的变化率相同。但它们的阶段可能是不同的。详细分析了控制策略的可行性和频率跟踪的必要性。已经建立并测试了18 kVA基于DSP的三相逆变器。仿真和实验结果验证了理论分析。