首页> 外文会议>Annual conference of the Canadian Society for Civil Engineering >Effect of Scaled Distance on the Deflections of Concrete Columns to Near-field Blast Loading: A Numerical Investigation
【24h】

Effect of Scaled Distance on the Deflections of Concrete Columns to Near-field Blast Loading: A Numerical Investigation

机译:标度距离对混凝土柱在近场爆破荷载作用下挠度的影响:数值研究

获取原文

摘要

This paper presents an investigation on the effect of scaled distances on deflections of reinforced concrete columns under near-field loading using a numerical modelling technique. An explicit analysis tool, AUTODYN, was utilised in this study for modelling the nonlinear dynamic behaviour of reinforced concrete columns. The RHT and the 4340 steel constitutive models were used in modelling concrete and steel reinforcement respectively. The maximum column deflections occurred at points below the mid-height for blast loading from explosions with scaled distance of less than 1.0. The blast loading on the column was highly nonlinear at scaled distance of 0.25 while uniform at a scaled distance of 1.0.
机译:本文利用数值模拟技术研究了标度距离对钢筋混凝土柱在近场荷载作用下挠度的影响。在这项研究中,使用了显式分析工具AUTODYN来对钢筋混凝土柱的非线性动力行为进行建模。 RHT和4340钢本构模型分别用于对混凝土和钢筋进行建模。最大柱偏斜发生在标高距离小于1.0的爆炸引起的爆炸载荷的中等高度以下的点上。柱上的爆炸载荷在0.25的比例距离上是高度非线性的,而在1.0的比例距离下是均匀的。