首页> 外文会议>Annual conference of the Canadian Society for Civil Engineering >Effect of Scaled Distance on the Deflections of Concrete Columns to Near-field Blast Loading: A Numerical Investigation
【24h】

Effect of Scaled Distance on the Deflections of Concrete Columns to Near-field Blast Loading: A Numerical Investigation

机译:缩放距离对近场爆破负荷近柱偏转的影响:数值调查

获取原文

摘要

This paper presents an investigation on the effect of scaled distances on deflections of reinforced concrete columns under near-field loading using a numerical modelling technique. An explicit analysis tool, AUTODYN, was utilised in this study for modelling the nonlinear dynamic behaviour of reinforced concrete columns. The RHT and the 4340 steel constitutive models were used in modelling concrete and steel reinforcement respectively. The maximum column deflections occurred at points below the mid-height for blast loading from explosions with scaled distance of less than 1.0. The blast loading on the column was highly nonlinear at scaled distance of 0.25 while uniform at a scaled distance of 1.0.
机译:本文介绍了使用数值建模技术对近场负荷下钢筋混凝土柱偏转偏差的效果的研究。该研究中利用了一种明确的分析工具,用于建模钢筋混凝土柱的非线性动力学行为。 RHT和4340钢结构型模型分别用于模拟混凝土和钢筋。最大柱偏转发生在低于爆炸的爆炸中高度低于爆炸距离小于1.0的爆炸点。柱上的爆破负载在缩放距离为0.25的距离下非常非线性,而均匀距离为1.0。