In this paper, we discuss the issue of safety in robot-assisted fracture reduction. We define the hazards of robot-assisted fracture reduction and design safety control methods. Although a large reduction force is required to reduce femoral neck fractures, an unexpectedly large force produced by a robot may cause injury to the patient. We have designed two mechanical failsafe units and a software force limiter; this along with velocity control can guarantee a safe operation in reduction force. In addition, to reduce the movement of bone fragments as much as possible, we devised spatially constrained control methods for fracture-reduction robots. The fracture-reduction system was evaluated using simulated fracture reductions.
机译:在本文中,我们讨论了机器人辅助骨折减少的安全问题。我们定义了机器人辅助断裂减少和设计安全控制方法的危害。尽管需要大的减少力来减少股骨颈骨折,但是由机器人产生的意外大的力可能导致患者造成伤害。我们设计了两个机械故障保护单元和软件力限制器;这与速度控制一起可以保证减少缩减力的安全操作。另外,为了减少骨碎片的运动尽可能多,我们设计了用于减少骨折的机器人的空间限制控制方法。使用模拟裂缝减少评估骨折还原系统。