Room temperature vulcanized (RTV) silicone rubber is widely used in external insulation of electrical equipment for antipollution flashover because it has many merits such as superior hydrophobicity and migration of hydrophobicity, but it also has weakness such as poor aging performance. The study on the failure criterion of RTV silicone rubber is always a concern since there has been no generally accepted method for its failure criterion. Corona has an important effect on the hydrophobicity and its recovery performance of RTV silicone rubber. In this paper, tests were conducted to reveal the effect of corona on the hydrophobicity recovery performance, and a failure criterion has been proposed. PRTV (permanent RTV) silicone rubber, a commonly used nanocomposite, was selected as the samples to study the hydrophobicity and its recovery after different corona aging time. Before the onset of aging, the factors that affect the accuracy of the contact angle measurement were studied. Fourier transform infrared spectroscopy (FTIR) was employed to find the failure criterion. The results show that, the relatively accuracy of the test data of contact angle can be obtained with 4 μL water drops and proper grounding of the test sample for 2 min. It is also found that the hydrophobicity is permanently lost when the continuous aging time is longer than 70 h under the test conditions, and compared with the virgin samples through FTIR, the peak height of CH3(C-H), Si-CH3 and Si-O-Si in FTIR decreases by 64.9%, 47.0% and 25.9%, respectively for the aged samples. It is suggested that, the variation of peak height of CH3(C-H), Si-CH3 and Si-O-Si in FTIR can be taken as the quantitative index of failure criterion of RTV silicone rubber.
机译:室温硫化(RTV)硅橡胶广泛用于防污觉闪络电气设备的外部绝缘,因为它具有许多优异的疏水性和疏水性的迁移,但它也具有较差的老化性能。对RTV硅橡胶的故障标准的研究始终是一个问题,因为它没有普遍接受其失效标准的方法。电晕对RTV硅橡胶的疏水性及其恢复性能具有重要作用。在本文中,进行了试验以揭示电晕对疏水性回收性能的影响,并提出了失效标准。 PRTV(永久RTV)硅橡胶是一种常用的纳米复合材料,作为研究疏水性及其在不同电晕老化时间后的恢复的样品。在衰老开始之前,研究了影响接触角测量的准确性的因素。使用傅里叶变换红外光谱(FTIR)来找到故障标准。结果表明,通过4μL水滴获得接触角的测试数据的相对准确性,并将测试样品适当接地2分钟。还发现当在试验条件下连续老化时间长于70小时时,疏水性永久损失,并与通过FTIR的原始样品,CH3(CH),Si-CH3和Si-O的峰值高度相比对于年龄样品,FTIR中的-SI分别降低了64.9%,47.0%和25.9%。建议,FTIR中CH3(C-H),Si-CH3和Si-Si的峰高的峰高的变化可以作为RTV硅橡胶的故障标准的定量指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号