首页> 外文会议>IEEE electrical insulation conference >Round-robin test of repetitive partial discharge inception voltage measurements on complete winding of 4 kW random-wound motor
【24h】

Round-robin test of repetitive partial discharge inception voltage measurements on complete winding of 4 kW random-wound motor

机译:循环试验对4 kW随机卷绕电机完整绕组的重复局部放电初始电压测量测量

获取原文

摘要

Measurements of repetitive partial discharge inception voltage (RPDIV) based on IEC 60034-18-41 using a stator coil winding of 4 kW random-wound motor have been performed in round-robin test (RRT) in Japan. A commercially available impulse power supply and a PD sensor were commonly used in the RRT. The present paper reports not only test procedure and results of RRT but also additional experimental data to clarify the mechanism of PD phenomena in the RRT.
机译:在日本的圆形罗宾试验(RRT)中,已经在使用4 kW随机缠绕电动机的定子线圈绕组的基于IEC 60034-18-41的重复局部放电初始电压(RPDIV)的测量。在RRT中通常使用市售的脉冲电源和PD传感器。本文不仅报告了RRT的测试程序和结果,还报告了额外的实验数据,以澄清RRT中PD现象的机制。