首页> 外文期刊>IEEE Transactions on Industry Applications >Partial-Discharge-Inception Testing on Low-Voltage Motors
【24h】

Partial-Discharge-Inception Testing on Low-Voltage Motors

机译:低压电动机的局部放电初始测试

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This is a review of one manufacturer's efforts toward testing National Electrical Manufacturers Association (NEMA) low-voltage motor insulation for compatibility with adjustable-speed drives (ASDs). Partial-discharge-inception-voltage (PDIV) measurements were selected as a tool to evaluate the future performance of the stator insulation system to resist deterioration by the drives. PDIV measurement is explained in terms of procedure and accuracy. Data are presented from tests made on motors from several prominent manufacturers.
机译:这是对一个制造商为测试美国电气制造商协会(NEMA)低压电动机绝缘与可调速驱动器(ASD)兼容性所做的努力的回顾。选择局部放电起始电压(PDIV)测量作为评估定子绝缘系统未来性能以抵抗驱动器劣化的工具。 PDIV测量以过程和准确性来解释。数据来自几个知名制造商的电动机测试。