Modeling and Testing of Laminated Curtain Wall Systems under Blast Loading

机译:爆炸荷载作用下夹层幕墙系统的建模与测试

获取原文

摘要

This paper focuses on the analytical modeling performed in conjunction with high explosive shock tube testing performed at the University of Kentucky (U.K.). Two 5 ft × 10 ft curtain wall systems were modeled, of which one was tested by U.K. using a shock tube. The modeling efforts were performed using an existing commercial code, LS-DYNA. The results indicate that the dynamic response in terms of the center deflection of the glazing and the mullion were closely predicted using the numerical models. Additional investigations and comparison with field tests are recommended to improve the design of the curtain wall system and the predictions of the numerical model.
机译:本文着重分析与在肯塔基大学(英国)进行的高爆炸冲击管测试一起执行的分析模型。对两个5英尺×10英尺的幕墙系统进行了建模,其中一个由英国使用减震管进行了测试。建模工作是使用现有的商业代码LS-DYNA进行的。结果表明,使用数值模型可以精确预测玻璃和竖框的中心挠度的动态响应。建议进行更多研究并与现场测试进行比较,以改善幕墙系统的设计和数值模型的预测。