Acoustic angiography of tumor vascular perfusion following high intensity focused ultrasound ablation

机译:高强度聚焦超声消融后肿瘤血管灌注的声血管造影

获取原文

摘要

Perfluorocarbon contrast agents, both microbubbles and nanodroplets, are known to enhance high intensity focused ultrasound (HIFU) ablation. While it is known that HIFU ablation reduces vascular perfusion in tissue these effects have not been mapped with high-resolution imaging, such as acoustic angiography. We aimed to determine the acute and chronic effects of HIFU on tumors in the presence and absence of both microbubbles and nanodroplets. Pulsed HIFU (2 MPa, 1 MHz, 10% duty cycle, 1 Hz PRF for 5 s) was delivered to flank fibrosarcoma tumors (n=9). During HIFU, 4.5×108 microbubbles or nanodroplets were infused via tail vein catheter (n=3 per group). Tumor perfusion was assessed 15 minutes and 72 hours after HIFU delivery. Only microbubbles resulted in a significant reduction in vascular perfusion (66.2±15.2%, p<;0.05). Both nanodroplets and microbubbles reduced the growth rates of tumors, although not significantly. Tumors treated with microbubbles and nanodroplets during HIFU resulted in only 121±41% and 106±47% volume increases respectively compared to 177±65% for HIFU-only treated controls. These results suggest that vascular perfusion can be drastically reduced, and tumor vasculature can be remodeled with sub-ablative HIFU. Low pressure HIFU when combined with microbubbles has the potential to enhance the safety of HIFU therapy. The acoustic angiography technique applied herein is especially applicable for determining sub-ablative effects of ultrasound and contrast agents on vascular perfusion.
机译:众所周知,全氟化碳造影剂(微泡和纳米液滴)均可增强高强度聚焦超声(HIFU)消融。尽管已知HIFU消融可减少组织中的血管灌注,但这些效果尚未通过高分辨率成像(如声波血管造影)绘制出来。我们旨在确定在存在和不存在微泡和纳米液滴的情况下,HIFU对肿瘤的急性和慢性作用。脉冲HIFU(2 MPa,1 MHz,10%占空比,1 Hz PRF持续5 s)被输送到后侧纤维肉瘤肿瘤(n = 9)。 HIFU期间,通过尾静脉导管注入4.5×10 8 微泡或纳米液滴(每组n = 3)。 HIFU分娩后15分钟和72小时评估肿瘤灌注。仅微泡导致血管灌注显着减少(66.2±15.2%,p <; 0.05)。纳米液滴和微泡都降低了肿瘤的生长速度,尽管并不明显。 HIFU期间用微泡和纳米液滴处理的肿瘤分别仅导致121±41%和106±47%的体积增加,而仅HIFU处理的对照则为177±65%。这些结果表明,可以使用亚消融性HIFU显着减少血管灌注,并且可以重塑肿瘤血管。低压HIFU与微泡结合使用时有可能增强HIFU治疗的安全性。本文所应用的声学血管造影技术尤其适用于确定超声和造影剂对血管灌注的亚消融作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号