【24h】

Perspectives in Electric Energy Metrology

机译:电能计量的透视

获取原文

摘要

The actual conditions prevailing at outdoor (desert) electronic metering sites were profiled through in-situ measurements of meter surface temperatures and heat flows. The mapped field conditions were then simulated in a meter testing laboratory and accuracy tests performed on transformer-operated electronic meters. Analysis of the test data reveals the deleterious effect of high ambient temperatures on the measurement accuracy and precision of electronic meter indications. Based on the study results, measures are recommended to address concerns about the reliability/accuracy of energy measurement in uncontrolled desert environmental conditions.
机译:在室外(沙漠)电子计量网站上的实际条件通过仪表表面温度和热流的原位测量来分析。然后在仪表测试实验室和精度测试中模拟映射的现场条件,并在变压器操作的电子仪表上进行。对测试数据的分析揭示了高环境温度对电子仪表指示的测量精度和精度的有害影响。根据研究结果,建议采取措施来解决不受控制的沙漠环境条件下能量测量的可靠性/准确性的担忧。