首页> 外文会议>Chinese Automation Congress >Research on KRT Monitoring Instrument Alarm Threshold in Main Control Room of Nuclear Power Plant
【24h】

Research on KRT Monitoring Instrument Alarm Threshold in Main Control Room of Nuclear Power Plant

机译:核电站主控室KRT监测仪器报警阈值研究

获取原文

摘要

In this paper, the intake air gamma radioactive monitoring alarm threshold of nuclear plant main control room was studied for both under normal operation condition and accident conditions. According to two different layout schemes, gamma radiation dose rate of measuring point was calculated by the MCNP code under three typical accidents (including S3, DBA-LOCA and LOCA conditions). The results show that it is proper that to keep original value of the detector alarm threshold of improved main control room, it could provide effective radiation protection for indoor staff.
机译:本文在正常运行条件和事故条件下,研究了核电站主控制室的进气伽马放射性监测报警阈值。根据两个不同的布局方案,通过三种典型事故(包括S3,DBA-LOCA和LOCA条件)下的MCNP代码计算测量点的伽马辐射剂量率。结果表明,要保持改进的主控制室的检测器警报阈值的原始值是正确的,可以为室内工作人员提供有效的辐射保护。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号