首页> 外文会议>IEEE Conference on Electrical Insulation and Dielectric Phenomena >Fundamental Investigation of Discharge-Induced Fire from Damaged Ac Power Supply Cord
【24h】

Fundamental Investigation of Discharge-Induced Fire from Damaged Ac Power Supply Cord

机译:来自损坏的AC电源线的排放火灾的基本调查

获取原文

摘要

Unintentional discharge occurring from electrically and/or mechanically damaged power supply cords can cause a fire. It is difficult to detect the event with a conventional circuit breaker. To fabricate a reliable safety device for preventing fires, the better understanding of the phenomenon is essential. The aim of this fundamental work is to clarify physical mechanisms how the combustibles around a damaged power supply cord ignites. Using power supply cords in which some element conductors are disconnected deliberately, ignition of combustibles is reproduced in laboratory. It is suggested that arc discharge is the origin of the ignition, which is followed by short circuit of disconnected element conductors or disconnection of intact element conductors.
机译:从电动和/或机械损坏的电源帘线发生的无意放电会导致火灾。用传统的断路器难以检测事件。为了防止火灾,制造可靠的安全装置,更好地了解现象是必不可少的。这种基本工作的目的是阐明物理机制如何绕过损坏的电源线点燃。使用一些元件导体故意断开的电源线,在实验室中再现可燃物的点火。建议电弧放电是点火的起源,其后是断开元件导体的短路或完整元件导体的断开。

著录项