首页> 外文会议>IEEE Conference on Electrical Insulation and Dielectric Phenomena >Surface preparations on MV-sized cable ends for ramped DC breakdown studies
【24h】

Surface preparations on MV-sized cable ends for ramped DC breakdown studies

机译:用于斜坡直流击穿研究的MV尺寸电缆的表面制剂

获取原文

摘要

The rising demand for HVDC crosslinked polyethylene (XLPE) cable systems has put many novel products and solutions on the market within the recent years. In order to assess electrical performance of physical interfaces, DC breakdown studies of XLPE cable samples have been performed. For these samples, the surface of the XLPE in the cable ends has been modified using different techniques. Besides changing the surface preparation method, also the impact of the test conditions has been studied. A slowly ramped DC voltage has been used in order to study the breakdown characteristics for the samples. A great impact on breakdown voltage was found depending on which surface preparation was used. This highlights the fact that interfaces indeed play an important role for HVDC applications.
机译:HVDC交联聚乙烯(XLPE)电缆系统的上升需求在近年来在市场上施加了许多新颖的产品和解决方案。为了评估物理界面的电性能,已经执行了XLPE电缆样本的DC击穿研究。对于这些样品,电缆端部的XLPE的表面已经使用不同的技术进行了修改。除了改变表面制备方法外,还研究了测试条件的影响。已经使用缓慢升温的直流电压,以研究样品的击穿特性。根据使用哪种表面制备,发现对击穿电压的影响很大。这突出显示接口确实为HVDC应用发挥着重要作用的事实。