首页> 外文会议>International Conference on Optical MEMS and Nanophotonics >Thermoelectrically controlled varifocal micromirror for near aberration free imaging
【24h】

Thermoelectrically controlled varifocal micromirror for near aberration free imaging

机译:热电控制变焦微镜,用于近像差无像成像

获取原文

摘要

A close-loop-controlled miniature Peltier element was used to vary the temperature of a 1.2 mm diameter silicon-gold bimorph varifocal micromirror (VFM), thereby changing its radius of curvature due to differential thermal expansion of the two materials. By varying the VFM temperature from 10°C to 100°C, the radius of curvature (ROC) of the micromirror was measured to vary from 19.2mm to 30.9mm. The Zernike coefficients over this operational range were analysed to be less than a few micrometres. An imaging system utilising the VFM was assembled, and examples of the near aberration-free images obtained are presented.
机译:闭环控制的微型珀耳帖元件用于改变直径为1.2毫米的硅金双晶双晶变焦微镜(VFM)的温度,从而由于两种材料的热膨胀差异而改变其曲率半径。通过将VFM温度从10°C更改为100°C,测得微镜的曲率半径(ROC)为19.2mm至30.9mm。在此工作范围内的Zernike系数经分析小于几微米。组装了使用VFM的成像系统,并介绍了获得的近乎无像差图像的示例。