Analysis on orthogonal test of T-shaped concrete-filled rectangular composite steel tubular columns

机译:T形矩形矩形钢管混凝土组合柱正交试验分析

获取原文

摘要

By the analysis of four factors' influence on the ultimate bearing capacity, the ductility coefficient and the energy consuming ability of the T-shape concrete-filled rectangular composite steel tubular columns and comparison to the significance degree of influence through the orthogonal test,which are the axial compression ratio, the strength of the concrete, the thickness of the steel tube and the type of the cross-section, the result shows that: the thickness of the steel tube effects the ultimate load of the T-shaped concrete-filled rectangular composite steel tubular columns most; the type of the crosssection effects the ductility coefficient and the equivalent viscous damping coefficient most; the application of the developed T-shaped concrete filled rectangular composite steel tubular columns with restraining drag bar is beneficial to improve member's ultimate bearing capacity and seismic performance (ductility and dissipation capacity).
机译:通过分析四个因素对T形矩形矩形钢管混凝土组合构件的极限承载力,延性系数和耗能能力的影响,并通过正交试验比较其显着性影响程度。轴向压缩比,混凝土强度,钢管厚度和截面类型表明:钢管厚度影响T形矩形混凝土的极限荷载复合钢管柱最多;横截面的类型对延性系数和等效粘性阻尼系数的影响最大。所开发的带有约束拉力杆的T形填充矩形矩形组合钢管混凝土柱的应用有利于提高构件的极限承载力和抗震性能(延性和耗散能力)。