Usefulness of GafChromic EBT film for dosimetry beyond 8.0 Gy

机译:Grafchromic EBT薄膜用于超过8.0 GY的剂量测量的有用性

获取原文

摘要

The objective of this study was to extend the usable dose measurement range of Gafchromic EBT film (EBT). EBT has the advantages of high sensitivity and improved film uniformity up to 8.0 Gy over Gafchromic MD-V2-55 film (MD-V2-55). EBT samples were exposed from 0.3 to 80 Gy. Optical densities of the samples were measured using ES-2200 (Seiko Epson Corporation, Nagano, Japan). EBT has an absorption spectrum with a maximum absorption band centered at 630 nm. The wavelength position of a maximum absorption does not shift with increasing dose within usable dose range. High sensitivity measurement of density can be performed using measurement light of 630 nm. We designed a flat-bed document scanner with single emission spectrum centered at 630 nm (IR-4000, iMeasure, Inc.) for EBT. Optical densities of the samples were also measured using IR-4000. The optical density response characteristics obtained by the combinations of EBT/ES-2200 and EBT/IR-4000 were compared with those of MD-V2-55/ES-2200. As a result, optical densities of EBT increased from 8.0 to 80 Gy. From the optical densities the calibration curves of net optical density versus delivered dose for dosimetry could be obtained. The combinations of EBT/ES-2200 and EBT/IR-4000 had higher sensitivity of densitometry than MD-V2-55/ES-2200. The sensitivity of EBT/IR-4000 was highest. Error of dose measurements up to 80 Gy is within about ±5%, ±8%, and ±4% for MD-V2-55/ES-2200, EBT/ES-2200, and EBT/IR-4000, respectively. The IR-4000 with single emission spectrum can bring out the capacity of high sensitivity and accuracy of EBT up to 80 Gy.
机译:本研究的目的是延长Gafchromic EBT薄膜(EBT)的可用剂量测量范围。 EBT具有高灵气和改善的薄膜均匀性高达8.0 GY的优点,高达Gafchromic MD-V2-55膜(MD-V2-55)。 EBT样品暴露于0.3至80Gy。使用ES-2200(Seiko Epson Corporation,Jaagano,Nagano)测量样品的光学密度。 EBT具有吸收光谱,最大吸收带以630nm为中心。最大吸收的波长位置不会随着可用剂量范围内的增加剂量而转化。可以使用630nm的测量光进行密度的高灵敏度测量。我们设计了一个带有单个发射光谱的平板文件扫描仪,以630 nm(ir-4000,imeasure,Inc。)为EBT。还使用IR-4000测量样品的光学密度。将通过EBT / ES-2200和EBT / IR-4000的组合获得的光学密度响应特性与MD-V2-55 / ES-2200的组合进行了比较。结果,EBT的光学密度从8.0增加到80 Gy。从光学密度来看,可以获得净光学密度与输送剂量的剂量计量的校准曲线。 EBT / ES-2200和EBT / IR-4000的组合具有比MD-V2-55 / ES-2200更高的密度测量仪的灵敏度。 EBT / IR-4000的灵敏度最高。对于MD-V2-55 / ES-2200,EBT / ES-2200和EBT / IR-4000,高达80 GY的剂量测量误差在约±5%,±8%和±4%之内。具有单一排放光谱的IR-4000可以带出高度灵敏度和EBT精度高达80 GY的容量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号