In order to testify the feasibility of early detection of acute cerebral ischemic stroke by electrical impedance to-mography (EIT) technique, an acute cerebral ischemic stroke animal model was established by embolizing the animal's right middle cerebral artery through a infusion catheter, and the EIT images were recorded thereafter using a newly developed EIT system that was optimized for brain imaging. The EIT results showed that after 30 minutes calm period, the resistiv-ity in the target area increased rapidly in the following 4 hours, and increased continuously with a lower slope in the following 11 hours. Those results suggest that EIT is a sensitive method for detecting cerebral ischemic stroke, especially on its early stage.
机译:为了通过电阻抗(EIT)技术来证明早期检测急性脑缺血性卒中的可行性,通过栓塞通过输液导管和EIT来确定急性脑缺血性卒中动物模型。此后使用用于脑成像的新开发的EIT系统来记录图像。 EIT结果表明,在平静的30分钟后,目标区域中的抗蚀剂在下面的4小时内迅速增加,并在下列11小时内连续增加。这些结果表明,EIT是一种检测脑缺血性卒中的敏感方法,特别是在早期阶段。