首页> 外文会议>International conference on the physics of reactors;PHYSOR 2012 >CONTROL ROD REACTIVITY MEASUREMENT BY ROD-DROP METHOD AT A FAST CRITICAL ASSEMBLY
【24h】

CONTROL ROD REACTIVITY MEASUREMENT BY ROD-DROP METHOD AT A FAST CRITICAL ASSEMBLY

机译:快速关键组件上的杆滴法控制杆反应性的测量

获取原文

摘要

Rod-drop experiments were carried out to estimate the reactivity of the control rod of a fast critical assembly operated by CAEP. Two power monitor systems were used to obtain the power level and integration method was used to process the data. Three experiments were performed. The experimental results of the reactivity from the two power monitor systems were consistent and showed a reasonable range of reactivity compared to results from positive period method.
机译:进行杆滴实验以估计CAEP操作的快速关键组件的控制杆的反应性。使用两个功率监视器系统来获得功率电平和集成方法来处理数据。进行三个实验。与阳性时间法的结果相比,两个功率监测系统的反应性的实验结果一致,并显示出合理的反应性范围。