In film cooling experimental studies, due to the difficulty in measuring the surface heat flux variation, a Heat Flux Ratio (HFR) equation originally derived by Mick and Mayle [1], has been widely employed to calculate the surface heat flux distribution using the measured adiabatic film effectiveness and surface temperature. A close examination of the derivation process and applications of the HFR equation reveals two issues of concern. First, an implicit assumption was introduced by letting the wall surface temperature of the system without-film be the same as that which would occur with a film-cooled condition. A revised equation is then derived by removing this implicit assumption and incorporating the wall temperature change due to film cooling Secondly, a uniform value of the non-dimensional metal temperature (p (or film cooling effectiveness) has been used in all the previous applications of the HFR equation. This practice implicitly implies that a uniform wall temperature is distributed throughout the entire surface under film cooling, which is usually not the case in real conditions. A series of computational experiments are conducted to verify the revised HFR equation under different conditions as well as examine the validity of using a constant surface temperature in the HFR equation. Results reveal that using a constant value of (0.5 ~ 0.7) to calculate surface heat flux may result in a negative HFR in some simulated cases showing the commonly adopted value Φ=0.5~0.7. This could induce errors and give false HFR. The error is reduced in 3D cases because the streamwise wall temperature becomes more uniform than 2D cases. The difference between the old and new equations can reach about 20%. A conjugate wall cooling simulation shows negative HFR is possible in the region close to the film hole due to the heat conduction from the downstream hotter region into the cooler region near the film hole. Using the actual wall temperature as the Φ-value, the newly revised HFR equation produces the exact heat flux as calculated by CFD including the correct calculation of negative heat flux caused by the conjugate wall.
机译:在膜冷却实验研究中,由于难以测量表面热通量变化,最初由Mick和Mayle [1]推导的热通量比(HFR)方程已被广泛用于计算表面热通量分布。绝热膜的有效性和表面温度。仔细检查HFR方程的推导过程和应用,可以发现两个令人关注的问题。首先,通过使无膜系统的壁表面温度与在膜冷却条件下的壁表面温度相同来引入隐式假设。然后,通过消除该隐式假设并结合由于薄膜冷却而引起的壁温变化,得出修正的方程式。其次,在以前的所有应用中,均使用了无量纲金属温度的均匀值(p(或薄膜冷却效率))。这种做法暗含了在膜冷却下整个表面均匀的壁温分布,这在实际条件下通常不是这种情况,进行了一系列计算实验,以验证在不同条件下修正后的HFR方程为:结果表明,在某些模拟情况下,使用

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号